Fix broken Danfoss Ally TRV automation

Somehow I used the wrong variables last time around...
This commit is contained in:
Rune Juhl Jacobsen 2025-03-13 22:50:48 +01:00
parent ba83781b0d
commit d71116761d

View file

@ -53,9 +53,11 @@ conditions:
# cases.
- condition: template
value_template: |-
{% if state_attr(temperature_entity, 'temperature') is none %}
{# if the temperature entity doesn't have a state, e.g. if it's powered off #}
{% if states(temperature_entity) is none %}
False
{% elif state_attr(climate_entity, 'external_measured_room_sensor') == None %}
{# if the radiator has been unavailable #}
{% elif state_attr(climate_entity, 'external_measured_room_sensor') is none %}
True
{% else %}
{{
@ -72,7 +74,7 @@ actions:
# state.
external_temperature: |-
{% if (trigger.id is not defined) or (trigger.to_state.state in ['unavailable', 'unknown']) %}
{{ state_attr(temperature_entity, 'temperature') }}
{{ states(temperature_entity) }}
{% else %}
{{ trigger.to_state.state | float }}
{% endif %}